Main features:
| Measurement and metering | |
| Voltage | Phase voltage, line voltage |
| Current | Three-phase current |
| Active power | Split-phase and total active power |
| Reactive power | Split-phase and total reactive power |
| Apparent power | Split-phase and total apparent power |
| Power Factor | Phase-to-phase and total power factor |
| Frequency | 45-60Hz |
| Power measurement | |
| active power | forward/reverse active power |
| Reactive power | Positive/reverse reactive power |
| Communication function | |
| Communication protocol | MODBUS-RTU |
| Communication mode | RS485 |
| Parameters | Value | ||
| Applicable grid | 3 phase 4 wires, 3 phase 3 wires | ||
| Working power | Voltage range | AC/DC85~265V;DC18V~72V(Optional) | |
| Power consumption | <5VA | ||
| Accuracy Class | Active Power Class 1, others Class 0.5 | ||
| Input | Voltage | Rated | AC 100V,220V,400V |
| Power consumption | <0.4VA/Phase | ||
| Impedance | ≥200kΩ | ||
| Current | Rated | AC 5A(0.02A-6A) | |
| Power consumption | <0.2VA/Phase | ||
| Impedance | ≥0.1Ω | ||
| Frequency | 45Hz~65Hz | ||
| Switching input | Dry contact input, photoelectric isolation | ||
| Output | Switching output | Relay output;
can set any alarming power, default remote control |
|
| Analog output | 0~20mA/0~5V(Can be set) | ||
| Digital communication interface | RS485/Modbus-RTU | ||
| Pulse output | 1~2 channels electrical energy pulse,Four-quadrant power metering | ||
| Environment
|
Temperature | Operation temperature: -20ºC~55ºC, Storage: -25ºC~70ºC | |
| Humidity | ≤90%RH, non-condensing, no corrosive air | ||
| Altitude | ≤2500m | ||
| EMC electromagnetic compatibility test | Electrostatic discharge immunity test | GB/T 17626.2-2006:test level 4, test voltage 8kV | |
| RF electromagnetic field immunity test | GB/T 17626.3-2006:test level 3, test field strength of 10V / m | ||
| Fast transient pulse group test | GB/T 17626.4-2008:test level 2, current voltage 1kV, other 500V | ||
| Surge (shock) immunity test | GB/T 17626.5-2008:test level 4, test voltage 4kV | ||
| RF field induction conducted harassment immunity test | GB/T 17626.6-2008:test level 3, test field strength of 10V / m | ||
| Voltage transients, short interruptions and voltage changes in the immunity test | GB/T 17626.11-2008:current and voltage test error qualified | ||
| Oscillation wave immunity test | GB/T 17626.12-1998:Class B ITE test, qualified | ||