ATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy Meter

Product Details
Customization: Available
After-sales Service: 1 Years
Warranty: 1 Years
Still deciding? Get samples of US$ 60/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Private Owner
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
  • ATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy Meter
  • ATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy Meter
  • ATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy Meter
  • ATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy Meter
  • ATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy Meter
  • ATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy Meter
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
ATZ1000
Installation
Direct Connected
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Theory
Electronic Meter
Type
Power Meter
Certification
ISO, CE
Customized
Customized
Operating Range
AC/DC85-265V
Rated
AC100V/220V/400V
Communication
RS485 Modbus RTU
Operating Temperature
-25ºC~55ºC
Storage Temperature
-40ºC~70ºC
Altitude
≤2000m
Power Consumption
≤5W
Cut-out Dimension
67mm*67mm
H*W*D
72mm*72mm*55mm
Transport Package
Paper Carton + Pallets
Trademark
Antin
Origin
Hangzhou

Product Description

 

Product Description


The ATZ1000 series multifunctionpower Analyzerare featuredin accuratemeasurement and display of various power parameters:voltage,current,power,frequency,activepowerreactive power,forwardpower reverse power,power factor totalharmonic distortion,sub-harmonics,maximum demand,etc.insingle-phasetwo-wire,three-phase three-wire,and three-phase four-wiregrids Itis suitable for real-time power mon-itoring systems and is characterized byits mult-functionaliy,versatiliy,high stability andlong ife.The meter is suitable forallkinds ofhigh andlow-voltage grids with amaximumcurent of 9999 Aand a maximum voltageof 50000 V.Ithasan RS485 communication interface for remotecommunication and is idealfor power and energy monitoring.

Main Features:
  • Cycle sampling not less than 128 points,support telematcs, remote control,telemetry
  • Compatible with single-phase and three-phase full grid system typeaccess
  • Sub-phase and total full powerparameter measurement
  • Fractionalharmonic measurement can reach up to 63 times
  • Support RS-485 and Ethernet port communication
  • Communication rate up to 38400bps
  • Five-touch keyoperation,friendlyinterface settings
  • High-resolution large screen,wide view area with black characterson gray background
  • Sub-phase and total powerand current demand statistics
  • Demand calculation mode,update period,slip time can be set
  • Real-time display ofthe load ratio sector chart
  • Power factor histogram indication
  • Bidirectional metering,sub-phase active and reactive power metering
  • Unbalanced (NEUTRAL WIRE)current and voltage
  • Phase sequence judgment,phase angle display
  • Manual and automatic page flip,backlight delay can be set
  • 1A/5A transformertype access,variable ratio can be set
  • Intelligent setting offorward and reverse wiring of sub-phase transformer
  • DI input anti-shake timecan be set according to actual needs
  • DO output delay time can be set according toactual needs
  • SOE equipment full event record
  • Removable batteryfor easy maintenance
  • Dn housing,installation size 92*92mm,extrusion typeinstallation,no snap fastening needed
  • Plug and unplug connection
 

Product Parameters

 
Parameter Value
Applicable grid Three-phase four-wire, three-phase three-wire, single two-wire, three-phase three-wire PT
Working power Voltage range AC/DC85~265V
Power consumption

 

 

≤5W
Input Voltage Rated AC100V,220V,400V
Overload 1.2 times continuous, 2 times (10s)
Power consumption <0.4VA/Phase
Impedance ≥200kΩ
Current Primary current 1-9999A
Secondary input 1A or 5A
Short-time overcurrent 20 times the maximum current for 0.5 seconds
Power consumption <0.2VA/Phase
Impedance ≥0.1Ω
Frequency 45Hz~65Hz
Switching input Dry contact input, photoelectric isolation
Output Switching output Relay output; can set any alarming power, default remote control
Pulse output 1 channel electrical energy pulse
Accuracy index Voltage/current 0.5%
Frequency 0.2%
Power/power factor 1%
Active power Class0.5S
Reactive power CLass2
Communication Bus type RS485
protocol Modbus RTU
Baud rate 2400/4800/9600/19200/38400bps
Address range 1-247
Bus load 64pcs
Communication distance 1000m
Parity EVEN/ODD/NONE(default)
Data bits 8
Stop bit 1
Ethernet por Modbus
Environment Operation temperature -25ºC~55ºC
Storage temperature -40ºC~70ºC
Operating humidity ≤90%RH, non-condensing, no corrosive air
Storage humidity ≤95%RH, non-condensing, no corrosive air
Altitude ≤2000m
Installation category CATIII
Withstanding voltage capacity AC withstanding voltage 4KV/1min Pulse withstanding voltage 6kV - 1.2µS waveform
IP Class IP51(Indoors)
Insulation class 2
Average trouble-free operation time ≥50000h
EMC electromagnetic compatibility test Electrostatic discharge immunity test GB/T 17626.2-2006:test level 4, test voltage 8kV
RF electromagnetic field immunity test GB/T 17626.3-2006:test level 3, test field strength of 10V / m
Fast transient pulse group test GB/T 17626.4-2008:test level 2, current voltage 1kV, other 500V
Surge (shock) immunity test GB/T 17626.5-2008:test level 4, test voltage 4kV
RF field induction conducted harassment immunity test GB/T 17626.6-2008:test level 3, test field strength of 10V / m
Voltage transients, short interruptions and voltage changes in the immunity test GB/T 17626.11-2008:current and voltage test error qualified
Oscillation wave immunity test GB/T 17626.12-1998:Class B ITE test, qualified
                               Conformity to Standards GBT22264.1-2008 Mounted digital display electrical measuring instrument Part 1: Definition and general requirements
GBT22264.7-2008 Mounted digital display electrical measuring instrument Part 7: Special requirements for multifunctional instruments
GBT22264.8-2009 Mounted digital display electrical measuring instrument Part 8:Recommended test methods
 ATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy MeterATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy MeterATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy MeterATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy MeterATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy MeterATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy MeterATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy MeterATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy MeterATZ1000 Digital Multifunction RS-485 Modbus RTU Pulse Output Power Energy Meter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier