AT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh Meter

Product Details
Customization: Available
After-sales Service: 1 Years
Warranty: 1 Years
Still deciding? Get samples of US$ 45/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018
  • AT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh Meter
  • AT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh Meter
  • AT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh Meter
  • AT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh Meter
  • AT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh Meter
  • AT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh Meter
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
AT180G
Display
Digital
Usage
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment
Three-phase Four-wire
Type
Energy Meter
Certification
ISO, CE
Customized
Customized
Voltage
AC100/220/230/400V
IP Class
IP51
Communication
Modbus
Operation Temperature
-25ºC~55ºC
Operation Humidity
≤90%Rh
Altitude
≤2000m
Average Trouble-Free Operation Time
≥50000h
Power Consumption
≤5W
Frequency
45Hz~65Hz
Accuracy Class
Active Power: Class1; Reactive Power: Class0.5
Insulation Class
2
Transport Package
Paper Carton + Pallets
Trademark
Antin
Origin
Hangzhou
HS Code
903033900
Production Capacity
50000 Per Month

Product Description

 

Product Description

 

AT180G Direct Type Three Phase Din Rail Energy Meter series are designed to collect, analyze and measure power parameters. AT180G series Three-phase din rail energy meter can support the measurement and analysis of various power parameters, such as voltage, current, four-quadrant power parameters, power factor, bi-directional active and reactive power etc. This series of products have RS485 communication interface, the highest baud rate support 38400bps, support Modbus, DLT645 and other communication protocols, can easily realize remote data reading. Meanwhile, it adopts LCD display, which can view and set various measurement parameters locally, and the product has password protection function to ensure the data security of the product.


Main Features:
  • Multifunctional parameter measurement
  • Support bi-directional power metering
  • Support direct access type, CT variable ratio access
  • Support 1-channel pulse optocoupler output interface, output parameters configurable
  • Support RS485 communication function, support Modbus RTU protocol
  • Standard 4-mode digital width, TH35-7.5 type din rail mounting
  • Large LCD display, white backlight, backlight lighting time adjustable
  • LCD refresh time: 1 second, support manual page turning and automatic display rotation (can be set to switch)
 

Product Parameters

Measured voltage Phase voltage, line voltage
Current
Frequency
Active phase power and total power
Reactive phase power and total power
Apparent Phase Power and Total Power
Split-phase and average power factor
Split-phase contact temperature and ambient temperature
Residual current, (through transformer)
Power measurement Forward and reverse active power
Forward and reverse reactive power
Communication mode RS485
 
   Parameters Value
Applicable Grid 3 phase 4 wires, 3 phase 3 wires
Working power Voltage range AC/DC85~265V
Power consumption <5VA
Accuracy Class Voltage, current ±0.5%
Power ±1%
Power Factor ±1%
Frequency ±0.2
Electricity ±1%
Frequency 45Hz~65Hz
Pulse constant 400imp/kWh
EMC electromagnetic compatibility test Electrostatic discharge immunity test GB/T 17626.2-2006:test level 4
RF electromagnetic field immunity test GB/T 17626.3-2006:test level 3
Fast transient pulse group test GB/T 17626.4-2008:test level 4
Surge (shock) immunity test GB/T 17626.5-2008:test level 4
RF field induction conducted harassment immunity test GB/T 17626.6-2008:test level 3
 
   Parameters Value
Applicable grid 3 phase 4 wires, 3 phase 3 wires
Working power Voltage range AC/DC85~265V
Power consumption <5VA
Accuracy Class Voltage, current ±0.5%
Power ±1%
Power Factor ±1%
Frequency ±0.2
Electricity ±1%
Frequency 45Hz~65Hz
Pulse constant 400imp/kWh
EMC electromagnetic compatibility test Electrostatic discharge immunity test GB/T 17626.2-2006:test level 4
RF electromagnetic field immunity test GB/T 17626.3-2006:test level 3
Fast transient pulse group test GB/T 17626.4-2008:test level 4
Surge (shock) immunity test GB/T 17626.5-2008:test level 4
RF field induction conducted harassment immunity test GB/T 17626.6-2008:test level 3


AT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh MeterAT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh MeterAT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh MeterAT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh MeterAT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh MeterAT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh MeterAT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh MeterAT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh MeterAT180G Three Phase Din Rail Energy Meter With RS485 Communication1 Output Kwh Meter

 

 

 